Contactors: Motor Control, Lighting, HVAC,
Power, 3 or 4 pole. Efficient New
Streamline, Smaller, Low Power Drain, Low
Noise, Easy to Install.
931810
32 Amp. AC-1, 18 Amp. AC-3
Normally Open (N.O.)
contacts
600V
32A. Incandescent, LED or resistive load
20A. Ballast, Motor 7.5HP @480V
Auxiliary contact 1NO/1NC
Power Lug Terminal Capacity AWG # 6 Coil
110/120VAC
Details*
Specifications
933210
50
Amp. AC-1, 32 Amp. AC-3 Normally Open (N.O.)
contacts 600V 50A.
Incandescent, LED or resistive load 32A. Motor control, 20HP@
480VAC Auxiliary contact 1NO/1NC
Power Lug Terminal Capacity AWG # 4
Coil 110/120VAC Details*Specifications
933210
120VAC $39.99
.
934060
60
Amp. 4 Pole
(Silent Operation)
Normally
Open (N.O.) contacts
For
120/220/277/Rated 500V,
7.5HP @240V, 15HP @460V
60A. Ballast, 7 KW@ 220VAC
Dimension: 2.2w x 3.3h x 2.5d inch
40Amp AC-1, 30Amp AC-3
Power Lug Terminal Capacity AWG # 4 Coil 110/120VAC
Specificationsadd DIN rail
934004
60Amp.
4 Pole N/C (Silent Operation)
Normally closed (N.C.) contacts
For
120/220/277/Rated 400V, 60A. Incandescent or resistive load AC1 32A. Ballast and General purpose AC3
Power
indicator, DIN mount Dim: 2.2 x 3.5 x 2.5 in
(55 x 90 x 70 mm)
Power Lug Terminal Capacity AWG # 4 Coil 110/120VAC Specificationsadd DIN rail
100 Amp. 3 Pole 933100
Normally
Open (N.O.) contacts
Rated 600V,
2 N/O, 2 N/C Auxiliary Contacts
20HP
@240V, 75HP @460V
Dimension: 3.3w x 5.3h x 4.1d inch 160Amp AC-1, 100Amp AC-3
Power Lug Terminal Capacity AWG #00 Coil Selection
120, 208, 230VAC add DIN rail
933181
85 Amp. 3 Pole
Contactor
Mechanical Held
Control Rated
600V,
2 N/O, 2 N/C Auxiliary Contacts
40HP
@240V, 60HP @460V
Resistive or LED Load 100Amp 135Amp AC-1, 85Amp AC-3 Dimension: 3.3w x 5.3h x 4.1d inch
Power Lug Terminal Capacity AWG #00
■
Momentary closure of the input terminals
will latch the Contactor ON,
■ Subsequent
closure will unlatch the Contactor OFF
• Retains status on power failure
Coil 110/120VAC
SPECIAL ORDER
40 Amp. 4 Pole 944120 Normally Open
(N.O.) contacts NEMA Definite purpose
10HP @240V, 15KW 277VAC
40 A. Ballast, 7 KW@ 220VAC
50A AC-1, 40A. AC-3 600V
Lighting - Refrigeration - HVAC
Dim: 2.75 x 3.5 x 3.0 in (70 x 90 x
75 mm)
Power Lug Terminal Capacity AWG # 4 120VAC coil
SPECIFICATIONS
(1) Special Order
40 Amp.
3 Pole 943120 Normally Open
(N.O.) contacts NEMA Definite purpose
10HP @240V, 15KW 277VAC
40 A. Ballast, 7 KW@ 220VAC
50A AC-1, 40A. AC-3 600V
Lighting - Refrigeration - HVAC
Dim: 2.75 x 3.5 x 3.0 in (70 x 90 x
75 mm)
Power Lug Terminal Capacity AWG # 4 120VAC coil
100 Amp. 4 Pole
Slim contactor
Normally
Open (N.O.) contacts For 120/220/277/Rated
500V,
50A. Ballast, 10 KW@ 220VAC, 15KW@277V 100A AC-1, 40A. AC-3 40A, 24VDC, DC Switching Power
indicator, DIN mount
Dim: 110 x 81 x 68 mm)
Dimensions
Power Lug Terminal Capacity AWG # 2/0 120VAC coil
100 Amp. 4 Pole
Slim contactor
Mechanical Held
Control 50A. Ballast, 10 KW@ 220VAC, 15KW@277V 100A AC-1, 40A. AC-3 40A, 24VDC, DC Switching
Resistive or LED Load 100Amp Power
indicator, DIN mount
Dim: 120 x 81 x 68 mm)
Power Lug Terminal Capacity AWG # 2/0
■
Momentary closure of the input terminals
will latch the Contactor ON,
■ Subsequent
closure will unlatch the Contactor OFF
• Retains status on power failure
Coil 110/120VAC
933021
Miniature Contactor 20Amp, 3 Pole,
120VAC Coil 2HP
@240V, 7.5HP @460V
1HP @120V, 20Amp AC-1, 12Amp. AC-3
Screw Clamp Terminals, 600V, 1 N.O. Aux.,
AC Coil Current Inrush 32VA,
Sealed 6VA
Dim: 1.7 x 2.5 x 2.3 in
(45 x 64 x 58 mm)
Power Lug Terminal Capacity AWG # 8
933020
Miniature Contactor 20Amp, 3 Pole,
12VDC Coil
2HP
@240V, 7.5HP @460V
1HP @120V, 20Amp AC-1, 12Amp. AC-3 Screw Clamp Terminals, 600V, 1 N.O. Aux., DC Coil Current Inrush/Sealed 250mA
Dim: 1.7 x 2.5 x 2.3 in
(45 x 64 x 58 mm)
Power Lug Terminal Capacity AWG # 8